Brand Name : Shengtai Instrument

Model Number : SH302B

Certification : ISO 4406

Place of Origin : China

MOQ : 1

Payment Terms : T/T

Supply Ability : 100000sets/year

Delivery Time : 7-15work-days

Packaging Details : wooden case

light source : semiconductor laser

particle size range : 0.8 um to 600 um (according to different sensors)

detection channels : 16 channel, the particle size of any Setting

resolution : better than 10%

repeatability : RSD<2%

viscosity range : the maximum 350 CST

sampling volume : 0.2 ~ 1000 ml

sampling precision : better than that of plus or minus 0.5%

sampling speed : 5 ~ 80 ml/min

maximum vacuum pressure tank : 0.08 mpa

pressure chamber the most-positive pressure : 0.8 mpa

biggest particle concentration : 20000 / ml

power supply : 110 ~ 245 v AC, 50 hz, 70 w

appearance size : 340 mm ×410 mm ×650 mm

Contact Now

Automatic Oil Particle Counter Oil Industry Classic Methods NAS1638 And ISO4406

Automatic Oil Particle Counter Oil Industry Classic Methods NAS1638 And ISO4406

SH302B automatic oil particle counter is used to detect the size and number of the solid particles in the liquid, can be widely used in aerospace, electric power, petroleum, chemical industry, transportation, ports, metallurgy, machinery, automobile manufacturing and other fields, the hydraulic oil, lubricating oil, rock oil, transformer oil, insulating oil, turbine oil, turbine oil, gear oil, engine oil, aviation kerosene, water-based hydraulic fluid solid particle pollution tests such as oil, and organic liquid, polymer solution for detection of insoluble particles.

Automatic oil pollution particle counter uses "photoresist method" to measure particles, and adopts the classic methods of oil industry NAS1638 and ISO4406, and can be according to the requirements of users, built-in a variety of standards required by users.

Precision syringe type sampling system, to achieve constant sampling speed and accurate control of sampling volume.

Positive/negative pressure sampling chamber device, sample degassing and high viscosity sample detection.

Large color LCD touch screen, graphic menu display, touch operation, simple and convenient.

Oil Liquid Particle Counter for Detection of Oil Contamination

ISO 4406 Engine Oil Lubricant Oil Particle Counter

performance characteristics

The counting principle of light resistance (shading) method formulated by International Hydraulic Standards Committee is adopted

High precision laser sensor, wide test range, stable performance, low noise, high resolution

Adopt the high pressure injection pump sampling mode, can set the sampling volume, the sampling speed is stable, the sampling accuracy is high

Sampling system combined with positive and negative pressure can realize sample degassing, which is suitable for inspection and testing of different viscosity

Built-in pressure sensor, you can set the pressure value, and automatically judge the cabin air pressure, ensure safety

Built-in air purification system to ensure that the test is not polluted

Built-in multiple calibration curves, compatible with all common domestic and foreign standards for calibration

Built-in GJB - 420 - b, NAS1638, ISO4406 (GB/T14039), SAE4059E and Г OCT17216-71, and other common standards, support custom standard tests, and can according to customer requirements set the required standards

Built - in data analysis system, one test can give all standard test data and pollution level

The particle size can be set arbitrarily, with nearly ten thousand particle sizes built in, which is convenient for particle size analysis

Various sampling containers such as standard sampling bottles or sampling cups can be used to meet the testing requirements of different industries

Full function automatic color touch screen operation, support Chinese and English dual interface, easy to operate

Single channel and multi-channel calibration can be carried out to achieve automatic calibration function

With RS232 interface, it can be connected to computer or laboratory platform for data processing

With mass data storage, printing function, can store 1000 groups of data and support U disk data storage

Technical indicators

light source semiconductor laser
particle size range 0.8 um to 600 um (according to different sensors)
detection channels 16 channel, the particle size of any Setting
resolution better than 10%
repeatability RSD<2%
viscosity range the maximum 350 CST
sampling volume 0.2 ~ 1000 ml
sampling precision better than that of plus or minus 0.5%
sampling speed 5 ~ 80 ml/min
maximum vacuum pressure tank 0.08 mpa
pressure chamber the most-positive pressure 0.8 mpa
biggest particle concentration 20000 / ml
power supply 110 ~ 245 v AC, 50 hz, 70 w
appearance size: 340 mm ×410 mm ×650 mm weight: 15kg

Packing list

S/N Name Quantity Unit Remarks
1 Host 1 set
2 Liquid inlet pipe 2 meter
3 Drain pipe 2 meter
4 data line 1 piece
5 precision syringe 1 piece On the host
6 Power cord 1 piece
7 Instruction 1 copy
8 Packing list 1 copy
9 Certificate warranty card 1 copy


Product Tags:

Automatic oil particle counter

      

NAS1638 oil particle counter

      

ISO4406 oil particle count testing equipment

      
China Automatic Oil Particle Counter Oil Industry Classic Methods NAS1638 And ISO4406 wholesale

Automatic Oil Particle Counter Oil Industry Classic Methods NAS1638 And ISO4406 Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shandong Shengtai instrument co.,ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0